How can a type 2 surge protection device protect your electrical equipment from surges
A voltage surge can last for only a few microseconds, yet it
can damage control panels, electronic equipment and other connected loads.
Lightning-induced disturbances and switching operations can create these sudden
voltage rises. A surge protection device spd helps limit that voltage
and reduce the stress reaching downstream equipment.
A Type 2 surge protection device protects electrical
equipment by limiting transient voltage and diverting surge current away from
downstream circuits. It is commonly installed at distribution boards to reduce
the surge energy reaching connected equipment such as control panels,
automation systems and electronic devices.
What is a Type 2 surge protection device?
A surge protection device type 2 is installed in
low-voltage distribution systems to limit transient overvoltage. It is commonly
fitted at a distribution board after the incoming protection, protecting
circuits and equipment further down the installation.
Axis offers Type 2 SPDs for single-phase and three-phase
applications.
|
Protection point |
SPD type |
Main purpose |
|
Main incoming supply |
Type 1 |
Handles high-energy surge exposure, including
lightning-related surges |
|
Main distribution point |
Type 1+2 |
Combines Type 1 and Type 2 protection |
|
Distribution board |
Type 2 |
Limits transient overvoltage reaching downstream circuits |
|
Close to sensitive equipment |
Type 3 |
Provides additional protection for sensitive electronic
equipment |
How does a Type 2 SPD protect electrical equipment?
1. Limits excessive voltage
During a surge, the voltage across the circuit can rise far
above its normal operating level. Sensitive components may not withstand this
sudden increase.
A surge
protection device type 2 limits the transient voltage to a lower level,
reducing electrical stress on connected equipment. The remaining voltage is
referred to as the protection level of the SPD.
This value is known as Up, or voltage protection level,
and it is an important specification when matching an SPD to the withstand
capability of the equipment being protected.
2. Diverts surge current
A Type 2 SPD connects in parallel with the circuit rather
than directly in series with the load. When a surge occurs, the device provides
a path for the surge current, helping keep the abnormal current away from
sensitive equipment.
Axis Type 2 devices use Metal Oxide Varistors (MOVs). An MOV
changes its resistance with applied voltage, allowing it to conduct during a
surge and return to a high-resistance state during normal operation.
Check the SPD's surge-current ratings, such as In and
Imax, against the expected surge exposure rather than choosing a device
only because it has a higher kA rating.
3. Reduces damage from switching surges
Not every surge comes from a lightning strike. Switching
operations in an electrical installation can also create transient voltage
spikes.
This is where a surge protection device spd can help.
Type 2 devices are intended for distribution-level protection and are commonly
used to handle switching-related surges within the installation.
4. Protects downstream equipment
Equipment connected downstream can include PLCs, control
panels, automation systems, communication equipment and other sensitive
electronics. A surge reaching these devices can cause malfunction or permanent
damage.
A surge protection device type 2 is placed upstream
of these loads so that transient voltage is limited before it reaches them. The
SPD connection length and installation arrangement can affect the protection
available at the equipment.
5. Works as part of a complete protection system
A Type 2 SPD is one part of a wider surge
protection arrangement. In installations with higher exposure, Type 1 or
Type 1+2 protection may be used at the incoming panel, with Type 2 protection
at a downstream distribution panel.
Selection must still match the electrical system. Check
operating voltage, phase arrangement, discharge-current rating, voltage
protection level and earthing arrangement before choosing a surge protection
device spd.
What to check before choosing a Type 2 SPD
Before selecting a surge
protection device type 2, check:
- System
voltage
- Single-phase
or three-phase configuration
- Earthing
arrangement
- Maximum
continuous operating voltage (Uc)
- Voltage
protection level (Up)
- Nominal
discharge current (In)
- Maximum
discharge current (Imax)
- Required
protection modes
- Upstream
protection
- Installation
and connection requirements
These details help ensure the SPD matches the electrical
system, rather than being selected only by its surge-current rating.
At Axis, we offer Type 1, Type 1+2 and Type 2 surge
protection devices for different electrical applications, including
single-phase and three-phase systems. Our team can help identify the
appropriate SPD configuration based on system voltage, phase arrangement,
protection requirements and installation conditions.
Need a surge protection device type 2 for your
distribution system? Speak with Axis engineers about your system voltage, phase
configuration and protection requirements to identify the suitable
specification for your installation.
FAQs
Is a Type 2 SPD enough to protect a building from
lightning?
Not always. A Type 2 SPD provides distribution-level
protection, but installations with higher lightning exposure may also require
Type 1 or Type 1+2 protection at the incoming supply. The complete protection
arrangement should be based on the electrical system, lightning exposure and
applicable design requirements.
What is the difference between Type 1 and Type 2 SPD?
Type 1 SPDs are used at the incoming supply to handle
higher-energy surge exposure, including lightning-related surges. A surge
protection device Type 2 is commonly installed at distribution boards to
limit transient overvoltages reaching downstream circuits.
Can a Type 2 SPD protect equipment from lightning surges?
Yes. It can limit transient overvoltages linked to
lightning-induced surges. A suitable protection arrangement depends on the
installation and its exposure.
Where is a Type 2 SPD installed?
It is commonly installed at a distribution or subsidiary
panel downstream of the main incoming protection.
What is an MOV in a Type 2 SPD?
MOV means Metal Oxide Varistor. Its resistance changes with
voltage, allowing it to carry surge current during a transient event.
How do I select a Type 2 SPD?
Check system voltage, phase arrangement, maximum continuous
operating voltage, discharge-current rating, voltage protection level and
earthing arrangement.